Free · IBC 2021

Occupant load calculator

Occupant load, number of exits and stair and door width from IBC Table 1004.5. Type your spaces, or drop an IFC model for every room of every storey.

Have a BIM model? Every room of every storey, measured and drawn.

IFC2x3 · IFC4 · IFC4.3 · never uploaded

Spaces on one floor

  • sq ft=20
  • sq ft=40

    Restaurants, conference rooms, lounges and similar.

Occupant load

60

3,600 sq ft
main use: business areas (offices)

Exits from the story
2
Table 1006.3.3
Stair width, total
18 in
0.3 in/person · each ≥ 44 in
Doors, corridors
12 in
0.2 in/person · door ≥ 32 in

How it works Spaces in, exits out

The occupant load calculator with 4,200 sq ft of offices, a 750 sq ft break room and 900 sq ft of corridors, giving 84 occupants, 2 exits and the stair and door widths

1. Pick the use, type the area

Each space gets its function from IBC Table 1004.5. The load updates as you type.

The first floor of buildingSMART's Medical-Dental Clinic sample IFC, 154 rooms coloured by use with each room's occupants, 232 in total

2. Or drop an IFC model

Every room of every storey is measured, drawn and given a first guess at its use from its name. Shown: buildingSMART's clinic sample (CC BY 4.0).

The clinic's storeys with occupant load, exits, stair width and door width, and the CSV and IFC download buttons

3. Check, then export

Correct the amber guesses, then download a CSV, or the IFC with each room's occupant load written in.

IBC Table 1004.5 Occupant load factors

Floor area per occupant for each function of space, from the 2021 IBC. Divide the area by the factor; gross or net says which area to measure.

Gross: everything inside the exterior walls, corridors, stairs and toilets included.
Net: the room itself, without corridors, stairs, toilets, mechanical rooms and closets.

Function of spacesq ft / personm² / personArea
BusinessBusiness areas (offices)15013.94gross
Concentrated business use (call centers, trading floors)504.65gross
Information technology equipment facilities2024 IBC30027.87gross
Courtrooms, other than fixed seating areas403.72net
Assembly without fixed seatsUnconcentrated (tables and chairs)151.39net
Concentrated (chairs only, not fixed)70.65net
Standing space50.46net
AssemblyExhibit gallery and museum302.79net
Gaming floors (keno, slots, etc.)111.02gross
Stages and platforms151.39net
Assembly with fixed seatsFixed seats (count the seats)1 per seat––
Benches without dividing arms (length)1 per 18 in1 per 457 mm–
Seating booths (length at the backrest)1 per 24 in1 per 610 mm–
AssemblyBowling lanes (5 persons per lane incl. 15 ft of runway)5 per lane––
Bowling centers, additional areas70.65net
Exercise rooms504.65gross
Skating rinks, swimming pools: rink and pool504.65gross
Skating rinks, swimming pools: decks151.39gross
Library reading rooms504.65net
Library stack area1009.29gross
Locker rooms504.65gross
Kitchens, commercial20018.58gross
EducationalClassroom area201.86net
Shops and other vocational room areas504.65net
Day care353.25net
MercantileMercantile (sales floor)605.57gross
Storage, stock, shipping areas30027.87gross
ResidentialResidential20018.58gross
Dormitories504.65gross
InstitutionalInpatient treatment areas24022.3gross
Outpatient areas1009.29gross
Institutional sleeping areas12011.15gross
Industrial and storageIndustrial areas1009.29gross
Group H-5 fabrication and manufacturing areas20018.58gross
Agricultural building30027.87gross
Warehouses50046.45gross
Parking garages20018.58gross
Aircraft hangars50046.45gross
Accessory storage areas, mechanical equipment room30027.87gross
Airport terminalBaggage claim201.86gross
Baggage handling30027.87gross
Concourse1009.29gross
Waiting areas151.39gross

Fixed seats, benches and booths are Section 1004.6; concentrated business use is Section 1004.8 (not less than 1 per 50 sq ft gross). Mall buildings follow Section 402.8.2 and are not listed. Metric values are converted from the square-foot factors (1 m² = 10.764 sq ft).

After the occupant load Exits and egress width

Exits per story

Table 1006.3.3

1 to 500 occupants2
501 to 1,000 occupants3
More than 1,000 occupants4

One exit from a room, up to

Table 1006.2.1; 3 from 501, 4 from 1,001

A, B, E, F, M, U49
S29
R-2, R-3, R-420
H-4, H-5, I-1, I-2, I-3, I-4, R-110
H-1, H-2, H-33

Width per occupant

Sections 1005.3.1, 1005.3.2

StairsOther
Standard0.3 in0.2 in
Sprinklers + voice alarm0.2 in0.15 in

Not in Group H or I-2. Minimum stair and corridor 44 in (36 in under 50 occupants), door 32 in clear.

Built for plan review Checkable, private, BIM-ready

Calculate occupant load

Every number cited

Factors, exits and widths come from IBC 2021 Chapter 10, with the section next to each result.

No upload

IFC files are read by code in your browser tab. Nothing reaches a server.

Back into the model

Write each room's occupant load into the IFC as Pset_SpaceOccupancyRequirements.

Questions About occupant load

How do you calculate occupant load?

Divide the floor area of each space by the occupant load factor for its function in IBC Table 1004.5. A 3,000 sq ft office at 150 sq ft gross per person holds 20 people; a 600 sq ft restaurant dining room at 15 sq ft net holds 40. For fixed seating, count the seats (Section 1004.6). Add the spaces of a story together to size its exits, stairs and doors.

What is the difference between gross and net floor area?

Gross is the floor inside the exterior walls with nothing taken out: corridors, stairs, toilets, closets, interior walls and columns all count. Net is the area actually used for the function, without corridors, stairs, toilet rooms, mechanical rooms and closets. Offices, homes and stores use gross factors; classrooms, restaurants and assembly rooms use net factors. That is why the calculator counts a corridor at the floor's main gross use and leaves it out when everything around it is net.

What is the occupant load factor for a restaurant, an office or a classroom?

Restaurant dining with tables and chairs: 15 sq ft net per person (assembly, unconcentrated). Standing space such as a bar: 5 net. A commercial kitchen: 200 gross. Offices: 150 gross (business areas). Classrooms: 20 net, and shops or vocational rooms 50 net. Conference rooms are usually counted as unconcentrated assembly, 15 net.

How do you round the occupant load?

The IBC does not say. The calculator rounds each net-factor room up to a whole person, as most plan reviewers expect. Gross-factor rooms of the same use are added up first and rounded once per story, because the gross factor already describes the whole floor; rounding ten small rooms of a home one by one would overstate it. Show the working to see every division.

How many exits does a story need?

Table 1006.3.3: two exits or access to exits for 1 to 500 occupants, three for 501 to 1,000 and four above 1,000. A single exit is allowed only in the small cases of Section 1006.3.4, such as a first story of a business with no more than 49 occupants and 75 feet of travel. Rooms need two exit access doorways of their own above the limits of Table 1006.2.1: 49 occupants for most uses.

How wide do the stairs and doors have to be?

Multiply the story's occupant load by 0.3 inch for stairs and 0.2 inch for doors, corridors and ramps (Sections 1005.3.1 and 1005.3.2). In a building with sprinklers throughout and an emergency voice/alarm system the factors drop to 0.2 and 0.15, except in Group H and I-2. Minimums still apply: 44 inches for a stair or corridor (36 below 50 occupants) and 32 inches clear for a door.

How does the IFC model option work?

The calculator reads every IfcSpace with web-ifc in your browser, nothing is uploaded. It takes the area from the file's NetFloorArea or GrossFloorArea quantity, Revit's Area property, or the room's floor in the geometry, and guesses the use from the room name (Office, Corridor, Classroom). Unrecognised names are marked amber. Download IFC with occupant loads writes Pset_SpaceOccupancyRequirements into each space and leaves the rest of the file unchanged.

Which code edition does it use?

The 2021 International Building Code, Chapter 10, which most US states have adopted. The 2018 edition has the same Table 1004.5; the 2024 edition adds information technology equipment facilities at 300 gross, which is in the list and marked. NFPA 101 (the Life Safety Code) has its own table, and local amendments can change factors, so your building official has the last word.

Can I use this for the occupancy sign of an assembly room?

It gives the number the code starts from. Section 1004.9 requires the occupant load to be posted in assembly rooms; the posted number is what your fire marshal approves, which can be higher with an approved seating or aisle plan (Section 1004.5.1, never more than one person per 7 sq ft) or lower if the exits cannot serve more.

This calculator is a design aid, not a code review: local amendments and your building official decide.
Guides: Free IFC editor · Free IFC viewer · Architectural drawings · MEP meaning · BIM execution plan
Sources: IBC 2021, Chapter 10 Means of Egress (ICC) · IBC 2021, Chapter 2 Definitions (ICC) · 2024 IBC changes to Table 1004.5 (Allegion) · Medical-Dental Clinic sample IFC, CC BY 4.0 (buildingSMART) · IFC Pset_SpaceOccupancyRequirements (buildingSMART)

No model yet? Generate one from a brief

Describe the building and AIBIMTool drafts the program, floor plans and an IFC4 model with named rooms, ready for this calculator, Revit or Archicad.

Start free now
BIM model generated by AIBIMTool from a written brief